ááááá Home > Support > Downloads > Cables and Drivers > G3 > Red Lion Products


System
ABB
AC Tech
Adam
Allen Bradley
Alpha Gear
Alstom
Animatics
Applied Motion
Automation Direct Koyo (PLC Direct)
BACnet
Baldor
Banner
Beckhoff ADS
BETA LaserMike
Bristol Babcock
CAN
Caterpillar
Cognex
Contrex
Control Techniques
Cruisair Controllers
CTC
CTI
Danfoss
Delta Computer Systems
DeviceNet
Dometic
Dupline
Eaton
Elmo
EMCO
Emerson
Emerson Process
Ethernet IP
EZ Automation
Festo
FlowCom
Garmin
GE
Giddings & Lewis
Hardy Instruments
HBM
Hitachi
Honeywell
ICP
IDEC
ifm
IMO
Indramat
Intelligent Actuator
Ircon
J1939
KEB
Keyence
King
Klockner Moeller
KollMorgen AC Drives
Koyo
Krohne
Lenze
LG/LS
Maguire
Matsushita
MicroMod Automation
Microscan
Mitsubishi Electric
Modbus
Modem
Motrona
MTS
N-TRON
Omni
Omron
Pacific Scientific
Parker
Pason
Phoenix Contact
PPT Vision
Profibus
Quicksilver
Red Lion Products
Rexroth
Schneider
Schneider-Telemecanique
SEW
Siemens
SMA
SMC
SPI
Square D
SSD Drives / Eurotherm
Telemecanique
Toshiba
Unitronics
Yamaha
Yaskawa
Yokogawa

:: Red Lion Products ::

For G3 Kadet Cables and Drivers please see this Tech Note
For G304K200 unit programming cable order CBLUSB4K
For G307K200 unit programming cable order part number CBLUSB7K
For G304K000 and G306K000 unit programming cable order part number CBLUSB23
For conversions for generation 1 to 2 see tech note TNG3K4 for G304K to G304K2 or TNG3K6 for G306K to G307K2
For G3 Kadet unit programming cable order part number CBLUSB23

G3, Modular Controller, and Data Station Plus
For RS-232 unit programming cable order part number CBLPROG0
For USB cable order part number CBLUSB00

For a specific Red Lion Products communications cable, see below...

Driver Name Literature Hardware Cable
Big Flexible Display (BFD)  Refer to
G3BFDM manual.
Refer to
G3BFDM manual.
CBLRLC05
RS485 2-wire
G3 4K2/7K2 Programming via RS232
PC to 4K2/7K2
 Refer to G3 and Crimson manual.PC COM Port
and 4K2/7K2
CBLPRO4K CBLPRO7K
G3 Programming via RS232
PC to G3.
 Refer to G3 and Crimson manual.PC COM Port
and G3 R232
CBLPROG0
G3 Programming via USB
PC to G3.
 Refer to G3 and Crimson manual.PC USB Port
and G3 USB
CBLUSB00
G3 to G3 via RS232
(Note 1)
 Refer to G3 and Crimson manual.G3
RS232
CBLPROG0 CBLRLC01 CBLRLC02
G3 to G3 via RS485
(Note 1 & 6)
 Refer to G3 and Crimson manual.G3
RS485 2-wire
CBLRLC05
RS485 2-wire
Modular Controller via RS232
G3 to Modular Controller.
(Note 1)
 Refer to Crimson manual and Red Lion product literature.Modular Controller
RS232
CBLPROG0 CBLRLC01 CBLRLC02
Modular Controller via RS485
G3 to Modular Controller.
(Note 1)
 Refer to Crimson manual and Red Lion product literature.Modular Controller
RS485 2-wire
CBLRLC05
RS485 2-wire
Paradigm Programming Port via RS232
G3 to Paradigm RS232 programming port.
(Note 1 & 5)
 Refer to Crimson manual and Red Lion product literature.Paradigm
RS232
Programming Port
CBLPROG0 CBLRLC01 CBLRLC02
Paradigm via RS232
G3 to Paradigm RS232 communications port.
(Note 1)
 Refer to Crimson manual and Red Lion product literature.Paradigm
RS232
Comms Port
P895803Z
Paradigm via RS485
G3 to Paradigm RS485 port.
(Note 1)
 Refer to Crimson manual and Red Lion product literature.Paradigm
RS485 2-wire
CBLPAR02
RS485 2-wire
Plant Floor Marquee  Refer to
PFM manual.
Refer to
PFM manual.
CBLPFM00
RS485 2-wire
Raw TCP/IP Active
G3 to Red Lion Instrument via Ethernet.
 Refer to Crimson manual and Red Lion product literature.Red Lion Instrument with Ethernet. Standard Ethernet cable.
Raw TCP/IP Passive
G3 to Red Lion Instrument via Ethernet.
 Refer to Crimson manual and Red Lion product literature.Red Lion Instrument with Ethernet. Standard Ethernet cable.
Red Lion Instrument via MODBUS
G3 RJ45 to Red Lion RJ11 via RS485 Modbus.
 Refer to Crimson manual and Red Lion product literature.Red Lion Product, RS485 Mobus via RJ11 (note 2)CBLRLC00
Red Lion, RLC Instrument
G3 to Red Lion Instrument via RS232, RS422, or RS485.
 Refer to Crimson manual and Red Lion product literature.Red Lion Instrument (note 4) Refer to system cabling information.
Red Lion, RLC Instrument (PAXCDC1C)
G3 to PAXCDC1C.
 Refer to Crimson manual and Red Lion product literature.PAXCDC1CCBLRLC00
Red Lion, RLC Instrument (PAXCDC2C)
G3 to PAXCDC2C.
 Refer to Crimson manual and Red Lion product literature.PAXCDC2CCBLGEN01
Serial Converters
G3 to Red Lion Serial Converter via RS232, RS422, or RS485
 Refer to Crimson manual and Red Lion product literature.ICM4 (Note 3a) ICM5 (Note 3b)CBLGEN01 CBLRLC00 Refer to system cabling information.


1. Any master/slave driver of the same type. For example Modbus.
2. Examples include DLC, PAXCDC40, PAXCDC4C, IAMS, and ITMS.
3a. Use system cabling located with the Red Lion Raw Serial Port.
3b. For RS232 use CBLGEN01. For RS485 use CBRLC00.
4. Examples include C48, Legend Plus, PAXCDC10, PAXCDC1C, PAXCDS20, PAXCDC2C, P48/T48 and PCU/TCU. Use sytem cabling located with the Red Lion Raw Serial Port.
5. See Communications with Paradigm Programming Port literature.
6. If using more than two G3s a breakout box, such as Red Lion's DRRJ45P6, DRRJ45T8 or DRRJ11T6, will need to be used.

To add a cable to your shopping cart,
simply enter the cable part number into the field below.


Privacy Policy | Terms and Conditions | Warranty Statement
Repair Order Policy | Return Policy

in Spanish in French in German in Italian in Chinese Search home