Build 711.000 (05/31/22) download

Fixed UNC Path Injection Vulnerability

 

Build 707.000 (05/15/18) download

Added support for USB mouse recovery mechanism
Fixed ABB COMLI driver not displaying values properly

 

Build 705.000 (04/9/18) download

Added driver for Banner VE Series Smart Camera
Fixed IP address not being updated with DynDns.com
Inhibited the use of camera drivers on Graphite Controllers

 

Build 703.001 (02/28/18) download

Added event buffer support to DNP3 Slave drivers
Added option (or changed the current behavior) to use a local broadcast to BACnet UDP/IP Master driver
Added Panasonic FP7 MEWTOCOL7 Serial and Ethernet drivers
Fixed DNP3 Slave driver not supporting Reals
Fixed DNP3 (TCP) reporting incorrect Timestamp

 

Build 702.004 (11/13/17) download

Fixes and Updates:
Added improvements to USB mouse compatibility
Fixed Graphite UIN4 module calibration returning incorrect values

 

Build 702.002 (9/11/17) download

Fixes and Updates:
Added 240 words-per-transaction limit to Ethernet Native Tags driver
Added ability to access L5K encoded add-on instructions
Added CAN Generic 11-bit/29-bit Identifier communications driver
Added support for SQL Queries
Added updates to Crimson Control Reference Manual Fixed BACnet UDP/IP Slave driver not properly responding to CIDR broadcasts
Fixed cell modem driver affecting use of RS-232 programming port
Fixed Crimson crash on importing L5K database
Fixed download failure when ROC drivers enabled on virtual ports
Fixed Find Usage of tags mapped to Crimson Control variables crashing Crimson
Fixed incorrect response from BACnet MS/TP Slave driver on Who-Is Request
Fixed J1939 DM message transmissions
Fixed SSD 638 Drive not working with Graphite HMIs

 

Build 700.000 (5/17/17) download

Fixes and Updates:
Added expansion of predefined TLP selection in ROC Enhanced driver
Added Heartbeat reset bit, heartbeat bypass bit, and counter reset support to E3
Added support for new Ethernet PHY used in the Data Station Plus and Modular Controller Masters
Fixed incorrect PID module range values in manual for ReqSP, AltSP and AltPV
Fixed J1939 driver not getting notified when comms block is deleted
Fixed Mail Manager causing reboot at start-up
Fixed SD memory cards not formatting to correct capacity

 

Build 697.003 (4/8/17) download

Fixes and Updates:
Fixed Mail Manager causing reboot at start-up
Fixed modem AT command-request timing violation

 

Build 697.002 (3/15/17) download

Updates:
Fixed Yaskawa 3000 IEC driver M Word Swap option affecting QL registers

 

Build 697.001 (2/28/17) download

Updates:
Added driver for Emerson Process Micro Motion Coriolis Meter
Added driver for Yaskawa MP3000iec PLC
Added support for Graphite Edge Controller
Fixed BACNet slave drivers causing a system reboot
Fixed C3 crashing on selection of model E3-8ISOTC
Fixed GMPID1 module not detecting alarm when no 4-20 input is connected
Fixed port and device numbers disappearing from status bar
Fixed Rebuild Comms Blocks utility links not working consistently
Fixed ROC driver TIME Data Type not correctly converting time after 12/30/16

 

Build 694.000 (12/19/16) download

Updates:
Added ability to receive the Address Claim PGN 60928 in the J1939 communications driver
Added master/slave drivers for DNP3 serial and Ethernet communications for Graphite HMI and
Graphite Core Controller models only
Added Secure Sockets Layer (SSL) support to e-mail service for Graphite HMI, Graphite Core Controller,
Data Station Plus ZR (DSPZR) and Modular Controller ZR (CSMSTRZR) models
Added support of SanDisk Ultra 50MB/s CompactFlash cards
Fixed Control Function Block DTCurDateTime producing incorrect outputs
Fixed error in custom web server pages when deleting tags from data tag section
Fixed Home Key not working in Graphite emulator
Fixed inability to enable Ethernet download when using System Menu
Fixed Mitsubishi Electric MELSERVO driver showing incorrect text
Fixed SQL Sync failing when string tags contain commas
Fixed SQL Sync service failing with data formatted using Numeric format, where Group Digits is set to Yes
Fixed SQL Sync service TCP Port limits to allow port numbers in the range (1..65535)
Fixed various drawing issues for Graphite emulator

 

Build 693.000 (10/18/16) download

Updates:
Added configurable Ping Register support for Yaskawa SGDH communications driver
Added database download warning for Graphite HMIs and Controllers when Control is enabled
Added Emerson Process ROC Protocol Enhanced TCP/IP communications driver
Added extra data registers to IDEC Micro 3 Series/ONC communications driver
Added I-Am subnet broadcast in response to local Who-Is requests for BACnet UDP/IP Slave driver
Added IEC 61131-3 Control support for Graphite HMI and Controllers
Added support for Graphite Core Controller
Added System Console for Graphite Controllers
Fixed BACnet Slave UDP/IP driver causing reboot after BMS Controller request
Fixed Crimson 3 software registration error
Fixed data-log default name format
Fixed gateway block direction enumerations
Fixed Graphite communications module not coming on-line after database image load from SD card
Fixed single character module names appearing blank in tag source field
Fixed time and date format not honored in integer tag from data-only web page
Fixed Yokogawa FA-M3 PLC TCP/IP master driver error with Graphite HMI units

 

Build 690.002 (09/20/16) download

Updates:
Fixed DB register mapping bug for Siemens S7 TCP/IP Master with TIA S7 Tag Import driver

 

Build 690.001 (09/14/16) download

Updates:
Added ability to adjust blink rate of alarm messages in primitive
Added ability to disable Modbus TCP/IP slave device
Added auto recovery for GMJ1939 module for bus failures
Added driver for Emerson Control Techniques FX Serial Driver
Added driver for Emerson Control Techniques Mentor II Master
Added driver for Emerson Control Techniques Motion Coordinator
Added driver for Emerson Control Techniques Pre-configured Modbus TCP
Added driver for Emerson Control Techniques Pre-configured Serial Modbus
Added driver for Emerson Control Techniques Unidrive M Pre-configured Modbus TCP
Added driver for Emerson Control Techniques Unidrive M Pre-configured Serial Modbus
Added driver for image capture from generic IP cameras (tested with Axis P1214-E model)
Added Graphite Module manual
Added Modular Controller Module manual
Added support for Graphite Tethered Rack module expansion system
Fixed data logger not following local separator in signatures column
Fixed Data Station Plus not generating GMC notice when fault occurs
Fixed display errors caused by tag prefixes
Fixed drag-and-drop of program allowing it to be visible in private folder
Fixed erroneous J1939 module status LED behavior
Fixed incorrect ability to add more than 16 modules to a Modular Controller database
Fixed incorrect ability to add more than one HSPA+ modem module to Graphite HMI, or to place in slot other than #1
Fixed KingBus driver causing configured hardware to stop and attempt restart
Fixed PTV and CSMSTRZR status light not indicating missing modules and/or terminating plugs
Fixed use of visibility feature causing lines to disappear completely

 

Build 683.002 (06/06/16) download

Updates:
Fixed GMHSPA & GMDN module connection failure

 

Build 683.001 (05/10/16) download

Updates:
Fixed tag numeric format with prefix, causing data entry error

 

Build 683.000 (04/18/16) download

Updates:
Added DevCtrl support to change target IP of OPC Master driver
Added ability to change the FTP server port number
Added Allen-Bradley Micro800 Series driver
Added DevCtrl function to Modbus TCP/IP Master driver to determine which device is in communication
Added DevCtrl support to Mitsu A/Q/FX TCP driver to change IP and TCP port
Added DevCtrl support of fallback IP to the GE TCP/IP Master via SRTP driver
Added Status Connect model featuring the Cloud Agent
Added support for extra characters in the alpha-numeric keypad
Added the ability to configure the duration and frequency that alarm messages appear in the Alarm Ticker primitive
Added time/date format option to Mail Manager
Fixed "Find Usage" not working for Graphite modules
Fixed Crimson startup issue when running under Windows 10
Fixed global popup position setting not working for keypad
Fixed ramping keypad not functioning for numeric formats that include a prefix
Fixed Scatter Graph causing crash when the Data Source is not configured
Fixed use of "Size Same As" function causing Crimson to crash

 

Build 678.002 (03/07/16) download

Updates:
Added ability to DSPLE to support "GetVersionInfo()" function
Added Advantech ADAM 4000 Series v2.00 communications driver
Added fill-under-curve enhancement to Trend Viewer data display
Added option to use auto-generated unique primary keys to SQL Sync
Fixed CTI Camp driver not automatically recovering from failure
Fixed Graphite HMIs sending malformed DNS requests
Fixed Japanese character displaying as "?"
Fixed Parker 6K communication driver’s real writes on Graphite HMIs
Improved Graphite module enumeration behavior

 

Build 675.000 (02/08/16) download

Updates:
Added Red Lion E3 Master TCP/IP driver
Added support for E3 I/O modules
Windows XP no longer supported (this version forward will not run under XP)

 

Build 662.006 (01/04/16) download

Updates:
Fixed download failures of databases containing a DNS configuration
Fixed Siemens S7 TCP/IP Driver gateway block issue when mapping data blocks

 

Build 662.002 (11/17/15)  download

Updates:
Added 32-bit access for Data Registers in IDEC Micro 3 Series / ONC communication driver
Added improved Multistate access in BACnet Slave communication drivers
Added "Unsigned" option for "Treat As" function in Emerson Enhanced ROC driver
Added ability of custom web page data entry to work without changing HTML code in existing applications
Added ability to change text color in the Event Viewer
Added support for a 250 response code from an FTP server
Fixed "PortInput" function returning partial data after timeout has elapsed
Fixed FtpPutFile and FtpGetFile user functions hanging when called with no memory card present
Fixed German translation of "Add Gateway Block"
Fixed IDEC driver not accepting a write of more than 17 "D" registers
Fixed inability to change certain TLPs in Emerson Enhanced ROC driver
Fixed inability to enter values for bits within a tag when tag is in Widget
Fixed incorrect addressing of certain gateway blocks in Siemens S7 TCP/IP Master driver
Fixed incorrect labeling of Kadet communications ports when running Crimson 3 in foreign languages
Fixed interference between Modbus "Automatic" and "Gateway" communications blocks
Fixed L5K driver generating duplicate "T->O" IDs
Fixed renaming of modules not being propagated to the source of mapped tags
Fixed SMTP authentication using MD5 Digest regardless of configuration
Fixed tag mapping changing when copying or importing tags associated with ABB TotalFlow Enhanced Master drivers
Removed mouse support from CSMSTRZR and DSPZR models

 

Build 657.003 (8/17/15) download

Updates:
Added Siemens S7 TCP/IP Master with TIA S7 Tag Import Driver

 

Build 657.001 (8/11/15) download

Updates:
Added communication improvements to ABB TotalFlow Enhanced Master drivers
Added expanded Application Number functionality for ABB TotalFlow Enhanced Master drivers
Added Start Command timeout to Siemens S7 via MPI Adapter driver
Fixed autotranslation not completing with some databases
Fixed autotranslation not working with long text boxes
Fixed CS and Graphite PID2 Module AltPV behavior
Fixed exporting of strings causing software crash
Fixed File Viewer Primitive when viewing files with malformed content
Fixed inability to configure translation when running in French
Fixed L5K V2 driver memory leak
Fixed Pason WITS driver real writes
Fixed USB keyboard input not working on G306 with USB Host Option Card

 

Build 647.002 (5/18/15) download

Updates:
Added improvement to J1939 driver multipacket send mechanism
Added new version of ABB Totalflow driver
Added support for new G3/MC/DSP HSPA+ modem option card
Added user interface to CANOpen PDO Slave Driver to allow manual TPDO configuration
Added warning box to Save Conversion function
Fixed address changing after tag creation
Fixed alarm tags containing invalid or non-working options
Fixed CAN PDO Slave Driver causing endless reboot
Fixed Crimson 3 crashing during import
Fixed Crimson crashing when viewing web page
Fixed emulator not working with G10R Graphite® HMI
Fixed Event History not functioning properly
Fixed G3 rebooting when custom web page is accessed
Fixed importing of data tags causing Crimson to crash
Fixed modem drivers not honoring baud rate setting
Fixed PDF viewer causing GMC
Fixed rebooting of G15 due to unreachable DNS server after database download
Fixed SaveCameraSetup function not working in Banner camera driver

 

Build 640.002 (4/8/15)

Updates:
Fixed intermittent power resulting in apparent loss of database

 

Build 640.001 (3/16/15) download

Updates:
Added PDF viewer primitive to ProducTVity Station (PTV)

 

Build 640.000 (2/23/15) download

Updates:
Added DeviceNet module support for Graphite HMIs
Added HSPA+ cellular modem module support for Graphite HMIs
Added PROFIBUS module support for Graphite HMIs
Added updates and corrections to Reference Manual
Added updates and corrections to User Manual

 

Build 639.000 (2/16/15) download

Updates:
Added configuration sorting to optimize communications in Emerson Process ROC Enhanced Driver
Added Opcode table access to Emerson Process ROC Enhanced Driver
Fixed AsTextR64 failing to display digits after decimal point
Fixed Emerson Process ROC Enhanced Driver clock CurrentTime writes
Fixed Emerson ROC with NRM radio module resulting in garbled data

 

Build 635.001 (1/26/15) download

Updates:
Fixed Crimson® crash and driver mapping failure when using Emerson Process ROC Enhanced Driver in build 635.000

 

Build 635.000 (1/5/15) download

Updates:
Added changes to Enhanced ROC Driver string mapping
Added clearer functionality of Modbus ping holding register
Added default event name for alarms as in Crimson 2
Added entry order option to Pages
Added extended range of data registers to Mitsubishi Q Series driver
Added increased Type-K thermocouple temperature range to all modules
Added TCP Port for TCP Link option to Options Menu
Fixed ability to map HCM value
Fixed Allen Bradley CSV import (DF1 and DH485 Driver) allowing invalid tag names
Fixed attaching of mouse causing G315 to reboot
Fixed BSAP master serial driver not communicating with device address 16
Fixed Crimson crashing when clicking on data logger or web server
Fixed CTC 2000 Series master driver not functioning
Fixed data dropping out on remote view during CF image save
Fixed data entry still functioning when group's show property is false
Fixed edge triggered and auto accept level alarms not operating correctly
Fixed enabling of custom home page breaking access to internal web pages
Fixed extracting database from G304K2 via USB to 232 converter
Fixed file conversion of G12 to G09 causing shell crash
Fixed font sizing issue on Graphite HMIs
Fixed G15 download stalling when writing data block 2
Fixed G304K databases not converting to Kadet 2 properly
Fixed G306K Kadet crashing when running Modbus drivers
Fixed GetCurrentUserName not being populated by webserver login
Fixed GetInterfaceStatus(2) not functioning
Fixed GMDIO module Active High/Active Low
Fixed Graphite battery reading not working
Fixed image file not loading from CompactFlash card as expected
Fixed incorrect button navigation in system menu
Fixed IsDeviceOnline() function not working with S7 300/400 TCP/IP driver
Fixed L5K V1 Driver reading too much data
Fixed L5K V2 driver failing to reconnect without a read
Fixed log time stamps not honoring time zone setting in Time Manager
Fixed Modbus Device Gateway Driver not responding to function code 16 properly
Fixed Modbus TCP/IP Slave not working on option card port
Fixed MPI card not communicating to multiple devices
Fixed PortInput not functioning as desired
Fixed PTV failing to output
Fixed system menu affecting touch screen calibration
Fixed system menu displaying unsupported options
Fixed tag import allowing for invalid character for tag name
Fixed tag import causing database crash due to illegal character in tag description
Fixed tag import/export issue
Fixed unit rebooting when trend viewer exceeds 24hr view
Fixed USB host copy being very slow

Build 624.005 (10/20/14) download

Updates:
Added ability to disable Modbus Gateway device
Disabled memory card access of Trend Viewer due to slow response time
Fixed continuous log Trend Viewer not showing all data
Fixed crashing of G306K when running Modbus drivers
Fixed L5k file causing Crimson to crash on import
Fixed L5K V2 driver requesting individual items
Fixed L5K V2.01 driver creating invalid named tags of wrong type
Fixed Modbus Device Gateway driver not responding to function code 16 properly
Fixed Modbus driver polling return errors
Fixed PortInput not functioning properly without carriage return
Fixed Trend Viewer not trending logs set to triggered snapshots properly

 

Build 624.000 (9/15/14) download

Updates:
Fixed CSTC8ISO modules not detecting failed input correctly
Fixed Galil/Yaskawa Universal SMC serial driver not allowing runtime to be stopped
Fixed GetInterfaceStatus(2) not functional
Fixed PFM not functional with Kadet and Graphite HMIs

 

Build 619.004 (8/12/14) download

Updates:
Fixed G307K2 Kadet failing to restart after power cycle

 

Build 619.002 (7/28/14) download

Updates:
Added ability to monitor Graphite module status
Added ability to set backlight timeout from a tag
Added access to CF data via trend viewer
Added additional image types to image file selection list
Added change to Profibus slave driver names
Added driver for KOYO Do-more PLC
Added indication of configured modules on module lists
Added modification to how data is displayed in Trend Viewer
Added modification to Modbus slave drivers to support reading more bits per transaction
Added option to define gateway address from system menu
Added option to force reload of image from CF card
Added option to not expect response to a Modbus write
Added option to send a single packet for PortPrint
Added option to send out single Ethernet packet that includes nulls
Added ping command to detect Ethernet devices
Added support to MakePic utility to support all product color formats
Added system menu to Crimson 3
Fixed alias input I/O not responding in AB L5K V2 driver
Fixed bool array issues with L5K V2 driver
Fixed BSAP UDP data appearing to jump
Fixed CSMSTRZR not allowing user to add modules
Fixed Graphite home icon not working in web server
Fixed inability to write long values via CAN PDO slave driver
Fixed Kadet 2 inability to write reals to Animatics Smart Motor
Fixed mouse cursor position not constrained to screen
Fixed navigating to a page crashing Crimson 3
Fixed PortInput command not ending with timeout
Fixed scaled tags causing fill mode to crash on primitive fill behavior
Fixed tag limits with fill-from-bottom feature causing crash with value greater than 12832
Fixed trend viewer with cursor not always showing data
Fixed widget binding crashing Crimson 3
Fixed widget not following array element assignments 

 

Build 615.004 (6/23/14) download

Updates:
Added Graphite module support for CAN protocol
Added Graphite module support for J1939 protocol 

 

Build 605.002 (2/11/14) download

Updates:
Added ability to access BACnet UDP slave device ID
Added ability to add more than one tag at a time to L5K V2 driver Available Address list
Added BACnet relinquish support
Added DevCtrl support to Enhanced ROC Driver to control group and unit numbers
Added DevCtrl support to L5K driver
Added digital inputs to ROC driver
Added disable of abort button during critical download period
Added mechanism to ROC driver to detect string access character length
Added missing security option to Chinese Crimson version
Added option to choose which logs are sync'ed with SQL database
Added option to configure timeout for "Auto Scroll" of event viewer
Added option to include 'FIRE_TRIGGERS' hint to SQL Sync
Added PID selection to drop down of ROC drivers
Added predefined point types to Enhanced ROC Driver
Added slot and route options to L5K V2 driver
Added square brackets around table and column names for SQL Sync
Fixed Allen-Bradely L5K v1 driver not communicating when routing path contains IP address string with an odd number of characters
Fixed Allen-Bradley L5K V1.04 driver corrupting tags when L5K file is imported
Fixed Allen-Bradley Native Tags via L5K V2.0 driver droping UDT comms when another device on protocol has communication error
Fixed Allen-Bradley Native Tags via L5K V2.0 driver tags not showing up in Resource pane
Fixed Allen-Bradley Native Tags via L5K V2.0 with removal of manual tag entry
Fixed Allen-Bradley Native Tags via L5K V2.00 driver not reading Real tag
Fixed Arial 32 Black font displaying improperly on G304K200
Fixed BACnet MS/TP connection causing data corruption
Fixed BACnet MS/TP data points not being auto-discovered
Fixed BACnet MS/TP Slave not functioning
Fixed BACnet UDP/IP Master stopping polling
Fixed BACnet UDP/IP not responding to Who-Is or issuing I-Am request on secondary Ethernet port
Fixed BACnet UPD/IP with 802.3 communications issue
Fixed conversion feature changing tag addresses
Fixed database causing G315 to lose time
Fixed database giving resource error when modifying data tags
Fixed database not loading to G12 with certain images included
Fixed Enhanced ROC Driver not reading string length correctly
Fixed Enhanced ROC Driver not using ping correctly
Fixed importing L5K crashing Crimson 3.0
Fixed J1939 custom PGN editor not working with more than 8 SPNs
Fixed mouse cursor not working on Graphite units
Fixed opening database in new build changing mappings
Fixed space being sent at end of a string even if NUL is selected
Fixed SQL Sync not always generating proper column type
Fixed SQL Sync of large logs failing
Fixed text not displaying properly on G304K2 and G307K2
Fixed TLP item in ROC driver showing as wrong data type

 

Build 603.000 (2/11/14) download

Updates:
Added 2D barcode primitive Added acknowledge bit to SQL Sync Fixed Cognex driver not displaying images properly Fixed Cognex image driver not working on Graphite models

 

Build 599.001 (2/11/14) download

Updates:
Fixed missed and repeated touches on Graphite models

 

Build 599.000 (1/27/14) download

Updates:
Added download-only mode for protection access
Added driver for Yaskawa A1000 TCP
Added gateway block export option
Added increase to Security Timeout Limit of four hours
Added SNMP traps for analog values
Added support for fonts larger than 200pt
Fixed Baldor Mint Host not writing reals correctly
Fixed data box covering trend area in Trend Viewer
Fixed deleting of last formatted tag crashing Crimson when "New Tag" is selected
Fixed DSP and MC RS485 port intermittent comms with Modbus Universal Master ASCII Mode and Port Sharing enabled
Fixed emulator web server showing incorrect colors
Fixed GetWeek returning incorrect value
Fixed GMUNI module not staying set for Type K thermocouple
Fixed going from build 502.001 to 582.001 causing SDO driver to change addresses
Fixed Graphite rebooting when scanned with IP scanner
Fixed Graphite sending malformed DNS requests
Fixed Graphite units occasionally missing screen touches
Fixed HEX Characters Show as ? with Arial Font
Fixed L5K V2.00 driver failing to reconnect to device
Fixed large database causing unit to reboot
Fixed new option to sort Alarm Viewer that changed default behavior
Fixed Sandisk CF card not being recognized
Fixed SMAnet driver not working with Sunny Boy model SB 7000US
Fixed Smart Duplicate
Fixed SNMP traps not being sent
Fixed Yaskawa Series 7 driver not functioning on Graphite models

 

Build 582.004 (1/7/14) download

Updates:
Fixed virtual ports not functioning on Graphite HMI models

 

Build 582.003 (12/23/13) download

Updates:
Fixed display flickering seen in Graphite G07 models

 

Build 582.001 (10/14/13) download

Updates:
Fixed alignment display defect in Kadet 2 HMIs
Fixed defective color rendering in Kadet 2 HMIs

 

Build 582.000 (10/4/13) download

Updates:
Added ability of Boulder Windpower CAN driver to send 0-8 bytes of data
Added ability of Modbus slave drivers to receive broadcast messages
Added ability of N-Tron® driver to work with additional protocol version
Added ability to sort alarm list by newest first
Added access to EM memory in Omron FINS Master driver
Added driver for ABB Totalflow G4
Added driver for Yamaha TS-X
Added error notice when database conversion configures both modes of single Kadet port
Added extended format control to AsTextR64WithFormat user function
Fixed "Verify" not working with CSSG module
Fixed AB Native Tags Driver not reading correct data
Fixed AsTextR64 not working with N-View™ driver
Fixed BACnet UDP/IP slave not sending unsolicited i-am
Fixed cell modem drivers causing Graphite units to reboot
Fixed crash caused by Edit/Undo of deleting driver from port after database conversion
Fixed emulator crashing in Kadet 2 and Graphite databases
Fixed flag tags not disconnecting from module outputs
Fixed Graphite trend buffer being limited to 5 minutes
Fixed grid not showing within configuration on some PCs
Fixed L5K 2.0 mapping of real tags being treated as integers
Fixed L5K pre-defined type inconsistencies
Fixed Modular Controller not initializing module unless data being accessed
Fixed N-View™ driver reporting incorrect values
Fixed Omron FINS Ethernet driver failing to communicate if PLC has I/O fault
Fixed OPCWorx not honoring tag's "Implied" type
Fixed PPP and Modem Server causing crash or restart of Graphite units
Fixed SMS via GSM Modem causing crash or restart of Graphite units
Fixed System Variable (i) not being recognized by flag triggers
Fixed tag names being altered after drag and drop action
Fixed vertical and horizontal bars not including SP in comms scan unless SP tag is on screen
Fixed vertical and horizontal bars not showing SP line unless data source is writeable
Fixed Yamaha driver not writing to PN register correctly

 

Build 579.003 (8/26/13) download

Updates:
Fixed G306A touch screen failure-to-start
Fixed G307K2 comms failure with AB ControlLogix systems
Fixed Graphite models occasionally staying in boot-loader mode during startup

 

Build 579.001 (8/19/13) download

Updates:
Added ability to use cameras with Graphite models
Added improved Graphite performance
Added USB mouse support
Fixed CF image not working properly on PTV
Fixed converting Graphite to MC not maintaining correct modules
Fixed entering a count of one in Scatter Graph Properties causing crash
Fixed Galil driver overwriting user-entered data with a zero
Fixed generic 29-bit CAN driver reading incorrect data
Fixed Merge Audio having no pitch
Fixed missing rop codes in BitBlt
Fixed PDF viewer not working on Graphite models
Fixed PNG images being inverted on Graphite models
Fixed PrintScreenToFile 8bit displaying images upside down on graphite models
Fixed PTV not displaying BMP images properly
Fixed software exception when mounting CF card on PTV

 

Build 573.002 (7/18/13) download

Updates:
Fixed touch calibration failure in Graphite HMI models

 

Build 573.001 (7/1/13) download

Updates:
Added support for Graphite HMI series

 

Build 548.005 (6/4/13) download

Updates:
Added driver for Omni Flow Computer

 

Build 548.001 (4/8/13) download

Updates:
Added function to force SQL sync
Added improved speed of FTP feature
Added increase in resolution of SQL sync period to minutes
Added increased number of TCP ports available in ROC Protocol Enhanced driver
Fixed ability to save inverted triangles
Fixed Alstom GEM80 JK slave not responding
Fixed data jumping between tags using the Native Tags via L5K File driver
Fixed database download problem caused by Allen Bradley native tags driver
Fixed entered value getting changed in Yaskawa TCP/IP MP2000iec driver
Fixed FTP of large file over cell modem failing
Fixed G307K2 crashing when quick plot primitive is full
Fixed G315 TCP buffer overflow causing GMC 24-2000-E0BA-3418
Fixed import of L5K file causing Crimson to stop responding
Fixed inability to disable remote control
Fixed inability to use both ports of XCRS expansion card
Fixed incorrect operator precedence
Fixed Modbus TCP/IP master incorrectly closing socket
Fixed PDF Viewer skewing colors
Fixed secure log showing name of last logged-in user
Fixed SQL Sync failing when logs don't use comma delimiters
Fixed TCP send window size management
Fixed trend viewer causing G306 to power-cycle
Fixed using Tag.AsText in event name not refreshing value

 

Build 530.003 (3/20/13) download

Updates:
Fixed ghosting of screen image on G307K2

 

Build 530.002 (3/11/13) download

Updates:
Added Verification of File Transfer Completion

 

Build 530.001 (2/25/13) download

Updates:
Fixed Stalling Communications in G304K2 and G307K2 Units

 

Build 530.000 (2/11/13) download

Updates:
Added DevCtrl Function to Switch Between Primary and Fallback IPs for Siemens S7-300/400 Driver
Added Enhancements to L5K Driver Performance
Fixed G304K2 Kadet 2 RS485 Aux & Comms Not Functional with RLC Instrument Driver
Fixed G306K Retentive Memory Loss

 

Build 523.003 (1/7/13) download

Updates:
Added Boulder Wind Power CAN driver
Added DevCtrl support to Beta LaserMike LS UDP driver
Added drivers for Beta LaserMike LS4000 & LS8000
Added generic 29-bit identifier CAN driver
Added increase of 60 seconds to device comms delay
Added N-Tron N-View™ support
Added support for new CSMSTRZR and DSPZR models
Fixed Beta LaserMike LS driver reporting Outputs:AnalogFullScale as a Real
Fixed converted database causing crash when modules selected
Fixed CSPID internal values being altered by program
Fixed database not loading into G315
Fixed DH485 driver not starting comms after power cycle on G304K2
Fixed EtherNet/IP driver not working with offset greater than zero
Fixed LG Master-K driver not functioning on Kadet models
Fixed Parker 6K TCP driver adding incorrect character
Fixed Smart Duplicate incrementing word but not bit number
Fixed tag mappings getting corrupted when converting from G304K to G315

 

Build 515.003 (11/14/12) download

Updates:
Fixed DF1 Master via PCCC/EIP driver causing reboot

 

Build 515.002 (10/31/12) download

Updates:
Added ability to pass tag metadata to BACnet client
Added driver for CANopen PDO Slave
Added driver for Cognex Cameras
Added driver for IFM Efector Dualis Object Recognition Sensor
Added driver for Microscan Hawk
Added driver for PPT VISION Smart Camera
Added Enhanced Emerson Process ROC driver
Added option for comms to CPU in a different rack via L5K driver
Fixed AS511 not able to read or write MW and the I/O
Fixed auto-translation failing
Fixed Banner iVu image not displaying on DSP or PTV
Fixed Banner Presence Plus P4 image colors and size off using PTV
Fixed Beckhoff driver not working on G306K
Fixed camera primitive image timing out after roughly 2 seconds
Fixed cause of error code GMC 2E-4000-75DC-3484
Fixed config not running in Spanish
Fixed Crimson crashing at various points when running in Spanish
Fixed Crimson crashing when copying mapped flag tags into a new database that does not have the PLC set up in comms first
Fixed database crashing Crimson when you view data tags
Fixed deleting devices or drivers with flag tags mapped crashing Crimson
Fixed disabling Mail Manager with tags set to E-mail-On-Alarm causing reboot
Fixed downloading converted database causing display/download failure in Kadets
Fixed Event Viewer stopping to refresh and not deleting older events
Fixed G307K2 runtime clock losing time
Fixed getting fault code 22-0000-0017-3418 without data logging enabled
Fixed GetVersionInfo always returning zero for Argument 3
Fixed Giddings and Lewis driver causing C3 to stop responding
Fixed inability to create arrays in CANopen SDO Master
Fixed inability to edit array elements from custom or data-only web page
Fixed inability to verify database when native tags driver in use
Fixed Keep-Alive behavior
Fixed Modbus ASCII Slave Driver performance issue
Fixed PID values not being retained after power cycle
Fixed ReadData() function not working correctly for string tags when mapped to Modbus
Fixed RS485 port appearing dead with a given database
Fixed Show Visible property on Trend View Objects not working with Expressions
Fixed Spanish Windows crashing when Page Properties is selected
Fixed viewing of Kadet tags on-line causing unit to reboot w/o GMC

 

Build 502.003 (10/10/12) download

Updates:
Fixed inability to download database which includes native tag addressing.
Fixed Parker 6K TCP driver adding incorrect character.
Fixed G307K2 runtime clock losing time.
Fixed DH485 driver losing communications after power cycle.
Fixed Kadet 2s entering restart loop after database download.

 

Build 502.001 (09/18/12) download

Updates:
Fixed reset of MAC ID numbers in Kadet models.
Build 502.000 (08/13/12)

Updates:
Added support for Kadet 2 models.

 

Build 493.005 (08/08/12) download

Updates:
Fixed retentive memory loss issue in Modular Controller and Data Station products.

 

Build 493.004 (07/26/12) download

Updates:
Added MicroMod TCP/IP Master driver.

 

Build 493.003 (07/06/12) download

Updates:
Fixed G3 intermittent comms when ARP request for gateway address not responded to.
Fixed inability to map tag to FST register message #1 parameter within Emerson Process ROC driver.
Fixed intermittent DH485 comms after TCP download.
Fixed internal clock of G315 running too fast.
Fixed LogComment function not adding comments to log.

 

Build 493 (06/26/12) download

Updates:
Added ability to password protect programs and data tags.
Added access to S registers in Mitsubishi A/Q/FX driver.
Added delay after Modbus master broadcast.
Added driver updates for BSAP slave advanced functionality.
Added GetAlarmTag(index) function to Resource pane.
Added improvements to MIF import in MicroMod driver.
Fixed adding 2nd Bristol Babcock BSAP device causing Modular Controller to reboot.
Fixed adding 2nd Bristol Babcock slave stopping comms to first unit.
Fixed alarm ticker not saving edge format.
Fixed BSAP UDP master driver not using device level timeout.
Fixed CSTC8000 channels 2-8 not working on mV setting.
Fixed fallback mode issue with SMAnet driver.
Fixed Garmin driver functionality.
Fixed Koyo ECOM master driver reverting to default device ID and protocol options.
Fixed L5K driver not reconnecting to all devices.
Fixed Merge Events not honoring the "no" selection.
Fixed ProducTVity Station not anti-aliasing properly.
Fixed ProducTVity Station not reducing to 256 colors properly on web server.
Fixed recipe writes using maximum record count.
Fixed SMS message relay not including message.

 

Build 484 (04/18/12) download

Updates:
Added ability to use custom landing page for remote view.
Added fallback TSAP and ability to communicate to redundant S7-400 PLCs.
Added increased measurement range of K-type thermocouple in CSPID2 module (to 1350°C).
Added module calibration utility within Crimson 3.0.
Added new module (CSTC8ISO) with increased measurement range of K-type thermocouple (to 1350°C).
Added new ramp/soak method.
Added standalone module calibration utility.
Fixed CSINV8 not reading zero voltage properly when in 0-10V mode.
Fixed CSPID ramp/soak ProfError acting at 90% of value.
Fixed ProfError in range of 328-655° causing profile to enter auto hold in CSPID2 module.
Fixed XCENET card locking up with heavy network traffic.

 

Build 477.003 (03/28/12) download

Updates:
Fixed decimal point not being honored in integer tag on data-only web page.

 

Build 477 (03/15/12) download

Updates:
Added DevCtrl support to change IP address of DF1 Master via PCCC/EIP driver.
Fixed "This is not a genuine copy of Crimson 3" error.
Fixed Trend Viewer causing G306 to reboot.
Fixed Class Selection under Animatics Smart Motor driver.
Fixed GALIL driver not updating registers.
Fixed ActiveAlarms failing with Data-Match-Event and Edge-Triggered Alarm tags.
Fixed BACnet UDP/IP Slave not sending after power-up.
Fixed Parker 6K TCP driver not displaying strings.

 

Build 469 (01/03/12) download

Updates:
Added SMAnet driver.
Added update to ROC driver.
Added update to Yokogawa FMA3 driver.
Fixed ReadData() function not working correctly for string tags.
Fixed no indication of lost communications when using Beta LaserMike driver.
Fixed multi-state tags not importing properly when using MicroMod driver.
Fixed flag tags not importing properly when using MicroMod driver.
Fixed Modbus ASCII slave driver not working.
Fixed incorrect TCP/IP receive window management.
Fixed time server not responding to client requests.
Fixed L5K driver failing to read arrays 246 elements long.

 

Build 459 (11/11/11) download

Updates:
Fixed database causing unit to reboot every three hours.
Fixed inability to communicate to ControlLogix through EN2T card.
Fixed touching blank screen areas causing buttons to activate.
Fixed XCCN option card not working in ProducTVity Station.

 

Build 454 (10/20/11) download

Updates:
Added BSAP Master driver update.
Added BSAP Slave driver.
Added increased number of major and minor divisions in the Trend Viewer.
Added SQL Sync to ProductTVity Station.
Added validation parameter for data entry items.
Fixed font size change with Hebrew usage.
Fixed L5K driver writes incorrectly formatted value.
Fixed PortPrint is only sending out 2 characters.
Fixed ProductTVity Station intermittent backplane communication.
Fixed ProducTVity Station doesn't honor transparency.
Fixed tag import allows invalid characters.

 

Build 443 (9/12/11) download

Updates:
Added BETA LaserMike drivers.
Added ProducTVity Station support.

 

Build 437 (8/15/11) download

Updates:
Added ability to disable spanning reads.
Added B&R Mininet driver.
Added Banner iVu driver.
Added camera image primitive.
Added DevCtrl support to BSAP driver.
Added easier creation of sequential mappings.
Added Eaton ELC Master updates.
Added Emerson Process Floboss via ROC driver.
Added Fallback IP for Siemens S7-300/400 TCP/IP driver.
Added improved handling of Beta drivers.
Added IQAN driver.
Added language forcing switch to installer.
Added manual update for digital signatures.
Added marquee display support.
Added more translation languages.
Added new property of "Read Anyway" to program area.
Added option to swap bytes in Modbus Master CRC.
Added PDF viewer model filter.
Added raise and lower keys to numeric entry keypad.
Added sending of events to raw port.
Added setup folder to hold MIBs etc.
Added SNMP driver.
Added support for Allen Bradley SLC 5/01.
Added support for preemptive writes.
Added system variable descriptions to manual.
Added update to "Using the Data Logger" section of user manual.
Added update to C3 manual.
Added update to Micromod TCP/IP Master driver.
Added Yaskawa A1000 serial driver.
Fixed alarm ticker flashing after alarm is accepted.
Fixed arrays in slave gateway block.
Fixed block write from master to slave.
Fixed C3 install when GoldX is present.
Fixed C3 not executing in Spanish.
Fixed CommitandReset() not saving properly.
Fixed crash on data entry for widget-within-widget.
Fixed crash on exporting CSV from Allen Bradley tag names driver.
Fixed CSMSTR C2 file import.
Fixed CSOUT not functioning when negative value is used for data low.
Fixed DevCtrl not returning FallBack IP Address for Modbus TCP device.
Fixed DeviceNet option card error.
Fixed DH485 comms failing with token generation.
Fixed display items getting shifted when page is shown as a popup.
Fixed Downloading Via Verify not prompting for untranslated programs.
Fixed flag tags not showing PLC address in bit selection.
Fixed gateway block settings reverting back to default values after data tag changes.
Fixed imported file causing config crash.
Fixed importing of Allen Bradley CSV file causing crash.
Fixed inability to change tag mapping to another module.
Fixed Micromod Extended Modbus.
Fixed Micromod MIF file import.
Fixed Modbus device gateway driver blocking direction.
Fixed Modbus TCP/IP Master not disabling Code 16 when writing Word as Long.
Fixed MPI comms failing with too many tags.
Fixed multiple GMCs with SQL Sync running.
Fixed Quick Plot causing emulator to crash.
Fixed Read Always error.
Fixed routing table error.
Fixed runtime code not passing array index.
Fixed shell error after conversion to Modular Controller GT.
Fixed Unexpected Reply Code 1.17.2.
Fixed unit crashing if SMS is too long.

 

Build 418 (4/21/11) download

Updates:
Added access to BACnet MS/TP Slave MAC and Device ID's from panel.
Added allowance for gateway blocks of a named comms item.
Added AMS ID for Beckhoff driver.
Added Animatics Smartmotor updates.
Added batch folder name validation functions.
Added CPU 943 support in Siemens S5 AS511 driver.
Added DynDNS additional domain support.
Added event tags to the interest list.
Added extension to 2F GMC watchdog timer.
Added G310 display type in title bar.
Added GoldX drivers to installation.
Added improved alarm poll efficiency.
Added improved text handling for C2 button import.
Added improved UTF-8 CSV encoding for logged data.
Added limitation of Data Log names to 8 Characters.
Added modified scripts to use 32-bit tools.
Added multiple CPU access to Mitsubishi Q series TCP/IP driver.
Added new SQL Sync Service.
Added Omron G9SP serial driver.
Added pending segment support to stack.
Added Report Network PGNs Diagnostic Function in J1939 driver.
Added revised C3 user manual.
Added routing to Square D driver.
Added SPI master driver.
Added tag alarm OnClear and OnActive.
Added timestamp change when signing file.
Added toggle to array tags in resource pane.
Added trimmed memory usage on Kadet.
Added various PDF viewer improvements.
Added VT220 firmware.
Fixed AB DF1 PCCC via EIP false data bug.
Fixed access of MicroLogix DF1 array elements greater than 254.
Fixed Adam 4000 series modules driver Kadet support.
Fixed AlarmAcceptAll OnAccept of an alarm.
Fixed Applied Motion parse bug and increased register range.
Fixed balloon help for concurrent batch properties.
Fixed broken folder binding.
Fixed C3 rich button support.
Fixed database crash upon open.
Fixed database not retained on G315.
Fixed database validation with BSAP driver and support upload.
Fixed DeviceNet EDS file encoding.
Fixed dialog boxes placement.
Fixed download broken by compression code.
Fixed emulator bug.
Fixed File Viewer scrolling.
Fixed G3RS0000 turns Off RS485 transmit line too quickly.
Fixed GetAlarmTag function missing.
Fixed IFM ASI Master via CoDeSys SP driver.
Fixed image update from USB when Sync disabled.
Fixed J1939 protcol will not allow custom PGN with SPN sizes of 16 bits.
Fixed large symbols display corrupted on G315.
Fixed legacy shadow import.
Fixed MC to MC conversion issue.
Fixed memory leak in nettle.
Fixed name of month displayed as "???" on G315's maximum keyboard size.
Fixed PDF Viewer will not render OpenType fonts.
Fixed random reboot problem.
Fixed rare USB stick problems after Ethernet download.
Fixed security keypad does not appear on pages requiring maintenance access.
Fixed symbols properties dialog fields.
Fixed Trend Viewer data items writing over buttons.
Fixed Trend Viewer usage issues.
Fixed upgrade race condition with CF.
Fixed URLs to use permalink syntax.
Fixed various bugs for Bristol Babcock BSAP Master driver.
Fixed various issues on CF verses Ethernet interplay.
Fixed WaitData always returns true.
Fixed WinCheck shows error inn wrong position after first file.
Fixed WinPCAP not installed when trying to run emulator.
Fixed write queue error handling.

 

Build 280 (3/2/11) download

Updates:
Fixed CF not recognized.

 

Build 278 (2/22/11) download

Updates:
Added data log sign modification.
Added Omron G9SP ethernet driver.
Fixed crash on load with tags in ethernet config.
Fixed File Viewer primitive.
Fixed FRAM/EEPROM and increased CF performance.
Fixed race condition on RTS control.
Fixed strange symbols in watch window.
Fixed wild write on startup.

 

Build 271 (1/26/11) download

Updates:
Added better checking of tag source device.
Added better checks on SetTag function.
Added better flash memory management.
Added block operations to NITP series drivers.
Added custom web page redirect.
Added expanded register ranges for GE SNP and SRTP drivers.
Added force for G306A boot loader upgrade.
Added Hebrew support.
Added increased bit address range in Yaskawa MPIEC driver.
Added increased program-thru buffer sizes.
Added L3 and L4 spaces to Modbus.
Added larger and maximum keypad fonts.
Added Micromod driver update.
Added Micromod extended Modbus update.
Added minor change to alarm handling.
Added nettle.
Added PDF Viewer primitive.
Added ping access to Koyo ECOM UDP/IP driver.
Added Port Fowarder driver.
Added reduced code size on Kadets.
Added Schneider PLC via Modbus serial and ethernet drivers.
Added second ethernet port to DSP/MC LE models.
Added Siemens USS driver process data in/out access.
Added Stiebel Eltron WPMII serial driver.
Added suppressed bi-directional explicit format code for standard font.
Added USB Host Expansion Card support.
Added USB Host Loopback support.
Added USB host option card CE mods.
Added UTF-8 encoding support for logged files.
Added web request parameter access.
Added Yamaha RCX series drivers.
Added Yaskawa MPIEC driver configuration update.
Fixed Animatics driver connection for new class 5 controllers.
Fixed autotranslate not working 100%.
Fixed bootloader limits for G308V2, G310E2 and G315.
Fixed C3 reference manual index.
Fixed CDL on G3 V2 platforms.
Fixed comment logging.
Fixed data logging file limit bug.
Fixed display of maximum in Yaskawa MPIEC driver.
Fixed DSP/MC option card filter.
Fixed Dupline via Modbus Kadet support.
Fixed Eurotherm 590+ and 690+/650 address selection.
Fixed further FLASH write issue.
Fixed further rare problem with widgets.
Fixed Hitachi response at low baud rates.
Fixed import of some DSP CD2 files.
Fixed inclusion of Add Port/Virtual in Kadets.
Fixed inclusion of OEM driver.
Fixed incorrect IsBatteryLow indication.
Fixed language forcing on Vista and Win7.
Fixed Lenze LECOM A/B Kadet support.
Fixed manual read arrays.
Fixed memory leak in nettle.
Fixed Micromod alarm handling.
Fixed minor memory leak with momentary button time delay.
Fixed new C2 platform V2 running V1 color emulation.
Fixed occasional 0x2F trap under heavy load.
Fixed OEM build startup problem.
Fixed problem with data log memory on Kadet.
Fixed problem with GetCurrentUserRights.
Fixed problem with ROM file renaming.
Fixed rare crash with widget security.
Fixed rare lockup on FLASH erase for G315.
Fixed security manager password change problem.
Fixed signature verification.
Fixed SMS On Message scan.
Fixed string batch file logging.
Fixed suppressed bi-directional explicit format code for all fonts.
Fixed translation of keypad title and status.
Fixed typo on DIO module name.
Fixed UI and web server task priorities for MC-based platforms.
Fixed UTF-8 encoding of CSV files.
Fixed V2 erratum.
Fixed web server idle bug.
Fixed Yaskawa F7 driver on Kadets.

 

Build 252 (10/18/10) download

Updates:
Added Acromag TCP/IP master driver.
Added Allen Bradley L5K driver boolean arrays support.
Added better bitmap cache control.
Added better passcode entry behavior.
Added better performance to log signatures.
Added better registration behavior on Windows 7.
Added better update of program tranlation indicator.
Added Bristol Babcock BSAP TCP/IP driver update.
Added defensive conversion of WMFs to EMFs.
Added device level word swap to Modbus TCP/IP master driver.
Added fallback IP address and DevCtrl() support - Omron FINS ethernet driver.
Added G3 Series HMI DNS configuration support.
Added G3 Series HMI DNS resolution function.
Added ignore read exceptions option to Modbus TCP/IP master.
Added improved Koyo UDP/IP drivers receive operations.
Added L5k driver support for large L5k files.
Added Metasys N2 slave driver update.
Added NITP based drivers update.
Added pending program translation indicator.
Added self-healing of zero-sized groups.
Added support for atomic bit writes.
Added time stamps to service logs.
Added updated driver filter.
Added updated strings.
Added Yaskawa MP2000iec driver.
Fixed CF reset.
Fixed crash on attempting to copy non-existent image.
Fixed dial and bar graph primitive label enabling behavior.
Fixed DST sync problem.
Fixed edit button cursor placement and improved editor behavior.
Fixed GPS time sync.
Fixed inconsistent G308 and G310 naming.
Fixed incorrect list viewer show page buttons logic.
Fixed incorrect lookup of programs during config.
Fixed NAN and INF handling in trend viewer.
Fixed occasional G304K hang-on-startup issue.
Fixed problem tags within folders in gateway blocks.
Fixed problem with DNS name resolution.
Fixed problem with some integer square roots.
Fixed problems with Modular Controller import.
Fixed SMPT server DNS lookup.

 

Build 241 (8/30/10) download

Updates:
Fixed alarm viewer won't accept some alarms.

 

Build 240 (8/18/10) download

Updates:
Fixed IP control bug.

 

Build 238 (8/13/10) download

Updates:
Added AB L5K driver file parser improvements.
Added ability to control CSV separator localization.
Added ability to parse spaces in details page list.
Added back support for discontinued G308K.
Added better automatic Treat-As configuration.
Added better Crimson 2.0 import behavior.
Added better default real name for security users.
Added better modem support.
Added CSV separator follows language setting.
Added firmware Size increase to 2.5M for G306A.
Added function to enable or disable battery check.
Added GetDeviceStatus to DSPLE.
Added increased memory limit for data logs.
Added improved DecToText when used with unicode text.
Added improved tag property preservation during import.
Added improved writes for Compumotor 6K serial driver.
Added IP address control.
Added MountCompactFlash API.
Added Modular Controller - data station C2 database import.
Added protection against crash during view data.
Added support for scaling of internal tags.
Added time and date primitive.
Added updated manuals.
Added warning on disabling IP download.
Fixed AB native tags serial driver - CD2 import support added.
Fixed appearance of Auto-Accepted alarms.
Fixed assume type info in code editor.
Fixed button hold time with security.
Fixed CAN EDS file user object report.
Fixed crash on certain scaled tags on Kadets.
Fixed crash on device tag recreation.
Fixed crash on view tags online.
Fixed generic language handling.
Fixed incorrect labels in code editor.
Fixed L5K array address selection behavior.
Fixed problem with dial gauge update rectangle.
Fixed problem with emulator programming port.
Fixed problem with modem on programming port.
Fixed problem with unicode in source.
Fixed renaming issues when dragging folders.
Fixed serial programming link.
Fixed Unitelway slave communications on V2 units.
Fixed wrong strings on code editor buttons.

 

Build 227 (6/28/10) download

Updates:
Added access to Modbus TCP/IP slave driver timeout.
Added Animatics driver dld's.
Added batch sending disable on raw serial port.
Added better disable logic on tag set UI.
Added better FTP client diagnostics.
Added better TCP socket scavenging.
Added better tolerance of slow links to DHCP.
Added call to master drivers service routine.
Added changes to tech support dialog.
Added Contrex ML-Trim et al driver update.
Added decreased minimum primitive size.
Added Eaton ELC master serial driver.
Added filter for selective drivers.
Added G308C2 to import list.
Added HBM AED/PW/FIT driver update.
Added Johnson Controls MetaSys N2 slave driver.
Added Micromod serial extended Modbus update.
Added Mitsubishi MELSEC 4 slave driver.
Added Modbus Device Gateway serial and TCP/IP slave drivers.
Added more functions to DSPLE.
Added new model dialog.
Added quick plot feature.
Added raw UDP/IP driver.
Added resizing of complex code editor dialog.
Added SendFileEx function.
Added support for G3ENET card.
Added support for L5K driver padded path.
Added support for larger lines during tag import.
Added Unitronics PCOM ascii serial and TCP/IP drivers.
Added Unitronics PCOM binary serial and TCP/IP drivers.
Added user configuration for Allen Bradley CSV data tag import.
Added V2 USB host/device reliability enhancements.
Added various TCP/IP stack improvements.
Fixed AB L5K driver alias tag handling.
Fixed alarm help parameters.
Fixed alarm viewer color import bug.
Fixed crash on large numbers of web page substitutions.
Fixed DecToText padding behavior.
Fixed device to G3 gateway block operation.
Fixed double negative on general real format.
Fixed errors on Modular Controller backplane comms.
Fixed G308A display support.
Fixed Garmin NMEA driver.
Fixed HasAccess on Kadets and emulator.
Fixed ICP DAS DCON driver analog input requests.
Fixed if statements with constant 0 expressions.
Fixed image file failure with some items.
Fixed import failure on some image primitives.
Fixed line doesn't honor display state.
Fixed Modbus Monitor ASCII driver - removed.
Fixed port sharing on Virtual Serial Port.
Fixed primitive denormalized rectangle bug.
Fixed problem with some denormalized lines.
Fixed rendering of comma in unicode tag export.
Fixed rounding error on integer data entry.
Fixed slave driver mapped blocks of direction "Device to G3".
Fixed spurious battery low message hangs in master V2.
Fixed upload from units programmed with CDI file.
Fixed USB race condition in boot loader.
Fixed various minor transparency issues.
Fixed web page order manipulation.
Fixed wrong color in tag set UI.

 

Build 222 (5/5/10) download

Updates:
Added updated version of English manual.
Fixed log file naming.
Added better over-range handling in numeric format.
Fixed disabled data entry limits on system tags.
Fixed handling of translated strings in Widgets.
Fixed handling of Unicode identifiers in compiler.
Fixed problem with buttons in certain viewers.
Fixed still-inaccessible time zone variables.
Added code to GotoPage to hide popups on null goto.
Added event viewer primitive coloring per event type.
Added FTP client performance improvements.
Added updated the English version of the manual.
Fixed comms extent update on tag duplication.
Fixed compressed textured bitmaps on 8bpp units.
Fixed occasional crash from sorting all items in navigation list.
Fixed occasional crash on import of cd2 with data entry validation.
Fixed occasional crash with old buttons with custom actions.
Fixed Ethernet/IP operation in emulator.
Fixed incorrect DecToText padding behavior.
Fixed occasional hang on error search.
Fixed problem with alarm viewer priority colors corrected.
Fixed problem when setting entry mode set via menu.
Fixed problem with dial gauge and read-only tags.
Fixed problem with mapping blocks not tracking renamed tags.
Fixed time zone system variables.
Fixed various data manipulation functions in Widgets.
Fixed various floating point functions in Emulator.

 

Build 219 (4/22/10) download

Updates:
Added color to event viewer primitive.
Added exposed port for BACnet UDP/IP slave driver.
Added Fatek serial and UDP drivers.
Added forwarded-NPDU support for BACnet UDP/IP slave driver.
Fixed alarm ticker - minor bug in priority color handling.
Fixed alarm viewer - priority colors.
Fixed bug and update Kollmorgen driver.
Fixed check for NULL after OEM crash.
Fixed config crash when using certain string functions.
Fixed erroneous acceptance of nulls in string constants.
Fixed Intelligent Motion Systems driver - removed.
Fixed Modular Controller properties in French.
Fixed MPI option card failing to work on V2 platforms.
Fixed ping command for Adam modules 4017 and 4018.
Fixed Profibus via MPI option card driver - removed.
Fixed Toshiba Series PLC Kadet word access.
Fixed two selections of MTS DDA slave version 1.00.
Fixed USB keyboard.

 

Build 217 (4/14/10) download

Drivers:
Mitsubishi FX2N encapsulated TCP/IP master driver.
CTI NITP TCP/IP master driver.
CTI NITP serial master driver.
CTI 25xx CAMP master serial driver.
CTI 2500/2572 CAMP TCP/IP master driver.
ICP DAS DCON serial master driver.
KEB DIN66019II TCP/IP master driver.
Siemens TI-500 series TCP/IP driver.
Siemens TI-500 series serial driver version 2.
Mitsubishi A/Q/FX series UDP/IP master driver.
PLC Direct Koyo EBC UDP/IP master driver.
Hardy Instruments Hardy Link driver.
Keyence KV Series driver.

Updates:
Fixed lockup on shutdown.
Added better source editor caret move / select behavior.
Fixed alarm siren behavior.
Fixed block position for line primitives.
Fixed French application data folder.
Fixed function help on Windows Vista and above.
Fixed Modular Controller on Windows Vista and above.
Fixed problem with Go menu and its prompts.
Fixed modules limit for Modular Controller.
Fixed name property now working.
Fixed EIP startup race condition.
Fixed modules string resource.
Fixed import bug - validation property not in CPrimRich.
Fixed layout and ordering of image links.
Fixed prompt text too big on G306.
Fixed crash on using string program result.
Fixed crash when deleted tag left on clipboard.
Fixed batch set deletion.
Fixed alarm light logic to match C2.
Added better data box import logic for array elements.
Added index array support for Danfoss VLT/FC driver.
Fixed J1939 configuration memory problem.
Fixed occasional crash on tag import.
Fixed problem when using Default Integer with scaling.
Added better logic for enabling complex expressions.
Added Chinese strings to installation bootstrap loader.
Added DNS Server to option list within DHCP client.
Added driver config object access to comms system.
Added improved detection of broken themes in Windows.
Added ability for hot link controls to take focus.
Added better driver tag import structure.
Added better help on Make Tags command. Added divide by zero protection to Trend Viewer.
Fixed crash when transactional writes disables.
Fixed race condition in mapping block startup.
Fixed rare memory leak in Web Server.
Fixed UI enables on array tag selection.
Added new image file icon.
Added support for more digits on line numbers.
Added a retry mechanism to mass storage driver.
Added a retry mechanism to V2 host controller.
Added new string resources.
Added Chinese language support to setup program.
Added fast language switching.

Features:
Added coloring options for primitives.
Added coloring options for symbols.

 

Build 207 (3/16/10) download

Enhancements:
This build contains a few extra drivers, especially for our expansion cards. We've also added a much-requested feature, namely the ability to import Allen-Bradley CSV files and automatically create tags within Crimson. International support has also been improved, with Korean fonts now being included in some models, complete with Hangul data entry.

Drivers:
AB Encapsulated DF1 TCP/IP driver.
Baldor MINT host serial master driver.
Dometic AirNet CAN driver.
J1939 driver.
Motrona LECOM Master serial driver.

Updates:
Better comms block formation.
Better driver tag import structure.
Better registration prompting logic.
Added improved C2 database import dialog.
Added improvements to RSLogix file import.
Added more pen choices to trend viewer.
Added most recent code signing keys.
Fixed 6" Kadet display size error.
Fixed array element bit selection syntax.
Fixed driver range errors in CANOpen SDO Master.
Fixed driver range errors in FlowComm.
Fixed extracted database reload on OEMs builds.
Fixed mapping block validation problems.
Fixed memory leak on some rich bar graphs.
Fixed non-refreshing alarm email selection.
Fixed occasional crash on F1 function help.
Fixed occasional debris from popup keypad.
Fixed problem with Kadet sending i386 DLDs.
Fixed problem with non-decimal TextToInt calls.
Fixed problem with pasting MC modules.
Fixed problem with PortInput on Kadets.
Fixed problem with re-importing some L5K files.
Fixed problem with some Kadet fonts.
Fixed sign extension of some PIDs in CDL.

Features:
BCD conversion as Manipulation option.
CD2 Baud rate import for CAN.
CD2 Baud rate import for DeviceNet.
Code to rebuild comms blocks more often.
Cursor to trend viewer.
Added faster boot loader for G315.
Added faster flash writes to G315.
Flashing control to alarm status bar.
Gridline support to scatter graph.
Korean gylphs to Hei 16 font image.
Localization of web server strings.
New Modular Controller memory layout.
OnAccept property to alarm objects.
RSLogix CSV file import facility.
Runtime display update watchdog.
Sanity checks on bound widgets.
Support for Korean Hangul text entry.
Support for L5K EMERGENCY_STOP.
Support for L5K ENABLE_PENDANT.
Time display to trend viewer cursor.
USB keyboards and barcode readers.